This creates a self contained system capable of supporting high density power loads.
Apc rack air containment system.
The ecoaisle is an intelligent thermal containment solution designed to increase cooling system efficiency while protecting critical it equipment and personnel.
The modular design and ability to retrofit to an existing netshelter sx rack enables medium to high density racks to be cooled in an autonomous.
The hot aisle containment system can be built using new american power conversion apc equipment or with existing apc.
The apc rack air distribution unit is a 2u fan unit that works with an existing precision air conditioning system to deliver cool air to the equipment contained in a rack enclosure.
The racs is a modular system that works with apc netshelter sx enclosures and inrow cooling units to provide maximum cooling predictability capacity and efficiency.
Apc inrack racs configurations 1.
Rack air distribution unit 2u 208 230v 50 60hz.
The hot aisle containment system encloses a hot aisle to collect and cool equipment exhaust making it available for cool air intakes.
The containment system is designed to create a separate environment for air distribution in order to prevent mixing of hot and cold air streams.
The containment system is designed to create a separate environment for air distribution in order to prevent mixing of hot and cold air streams resulting in a more predictable cooling pattern.
A hot aisle containment system hacs encloses the hot aisle to collect the it equipment s hot exhaust air allowing the rest of the data center to become a large cold air return plenum.
Hot and cold air containment systems designed to maximize cooling predictability capacity and efficiency at the rack row or room level.
The rack air distribution unit connects into the raised floor and pulls supply air directly into the enclosure.
Apc application note 90 rack air containment application guidelines and approved configurations by kevin dunlapabstractthe rack air containment system racs is a modular front and rear plenum for use in isolating the supply and return airbetween an apc netshelter sx rack enclosure and an apc inrow cooling unit.
This prevents the conditioned.
The rack air containment system racs is a modular front and rear plenum for use in isolating the supply and return air between an apc netshelter sx rack enclosure and an apc inrow cooling solution.
The rack air containment system racs is a mechanical ducting system that attaches to the front or rear of an enclosure to provide increased cooling capacity.
The rack air distribution unit is a 2u fan unit that connects into the raised floor and pulls supply air directly into the enclosure.